352 research outputs found

    The use of a non-absorbable membrane as an occlusive barrier for alveolar ridge preservation: A one year follow-up prospective cohort study

    Get PDF
    The aims of this study were to obtain preliminary data and test the clinical efficacy of a novel nonporous dense-polytetrafluoroethylene (d-PTFE) membrane (permamem®, botiss) in alveolar ridge preservation (ARP) procedures with a flapless approach. A traumatic extraction was performed in the premolar maxillary area, and a d-PTFE membrane was used to seal the alveolar cavity: no biomaterial was used to graft the socket and the membrane was left intentionally exposed and stabilized with sutures. The membrane was removed after four weeks and dental implants were placed four months after the procedure. The primary outcome variables were defined as the dimensional changes in the ridge width and height after four months. A total of 15 patients were enrolled in this study. The mean width of the alveolar cavity was 8.9 ± 1.1 mm immediately after tooth extraction, while four months later a mean reduction of 1.75 mm was experienced. A mean vertical reduction of 0.9 ± 0.42 mm on the buccal aspect and 0.6 ± 0.23 mm on the palatal aspect were recorded at implant placement. Within the limitations of this study, the d-PTFE membrane proved to be effective in alveolar ridge preservation, with the outcomes of the regeneration not affected by the complete exposure of this biomaterial

    Energy response of GR-200A thermoluminescence dosemeters to CO-60 and to monoenergetic synchrotron radiation in the energy range 28-40 KEV

    Get PDF
    7noThe response of LiF:Mg,Cu,P thermoluminescence dosemeters (type GR-200A) to monoenergetic radiation of energy 28, 35, 38 and 40 keV was evaluated with respect to irradiation with a calibrated 60Co gamma-ray source. High-precision measurements of the relative air kerma response performed at the SYRMEP beamline of the ELETTRA synchrotron radiation facility (Trieste, Italy) showed a significant deviation of the average response to low-energy X-rays from that to 60Co, with an over-response from 6 % (at 28 keV) to 22 % (at 40 keV). These data are not consistent with literature data for these dosemeters, where model predictions gave deviation from unity of the relative air kerma response of about 10 %. The authors conclude for the need of additional determinations of the low-energy relative response of GR-200A dosemeters, covering a wider range of monoenergetic energies sampled at a fine energy step, as planned in future experiments by their group at the ELETTRA facility.Published online first 02 March 2015partially_openembargoed_20160302F. Emiro; F. Di Lillo; G. Mettivier; C. Fedon; R. Longo; G. Tromba; P. RussoF., Emiro; F., Di Lillo; G., Mettivier; Fedon, Christian; Longo, Renata; G., Tromba; P., Russ

    Use of XR-QA2 radiochromic films for quantitative imaging of a synchrotron radiation beam

    Get PDF
    This work investigates the use of XR-QA2 radiochromic films for quantitative imaging of a synchrotron radiation (SR) beam. Pieces (200 7 30 mm2) of XR-QA2 film were irradiated in a plane transverse to the beam axis, at the SYRMEP beamline at ELETTRA (Trieste), with a monochromatic beam of size 170 7 3.94 mm2 (H 7 V) and energy of 28, 35, 38 or 40 keV. The response was calibrated in terms of average air kerma (1\uf02d20 mGy), measured with a calibrated ionization chamber. Films were digitized in reflectance mode using a flatbed scanner. The 16-bit red channel was used. The net\uf020reflectance was then converted to photon fluence per unit air kerma (mm-2 mGy-1). The SR beam profile was acquired also with a scintillator (GOS) based, fiberoptic coupled CCD camera as well as with a scintillator based flat panel detector. Horizontal profiles obtained with the two modalities were compared, evaluated in a ROI of 17.71 7 0.59 mm2, across the beam centre. Once corrected for flat field, the CCD profile was scaled in order to have the same average value as the normalized profile acquired with the gafchromic film. The same procedure was followed for the beam images acquired with the flat panel detector. Horizontal and vertical line profiles acquired with the radiochromic film show an uneven 2D distribution of the beam intensity, with variations in the order of 15\uf02d20% in the horizontal direction, while the statistical uncertainties evaluated for the radiochromic dose measurements were 6% at 28 keV. Larger variations up to 64% were observed in the vertical direction. The response of the radiochromic film is comparable to that of the other imaging detectors, within less than 5% variation

    Optimization of pixel size and propagation distance in X-ray phase-contrast virtual histology

    Get PDF
    X-ray phase-contrast coupled to high-spatial resolution imaging systems provides a high sensitivity for distinguishing soft tissue structures in small samples, thus being suited for X-ray virtual histology. Propagation-based phase-contrast tomography can deliver a considerable gain in signal-to-noise ratio (SNR) at small pixel sizes when it is combined to a suitable phase retrieval filter. We optimized acquisition parameters, namely the propagation distance and the pixel size, with the aim of providing adequate spatial resolution and sensitivity for virtual histology of breast surgery specimens, scanned with a phase-contrast microtomography (mu CT) system employing a commercial sCMOS detector at the SYRMEP beamline of the Italian synchrotron facility Elettra (Trieste, Italy). A pathological breast tissue sample was embedded in paraffin and imaged using a polychromatic synchrotron beam at an average energy of 24 keV. The high numerical optical aperture of the imaging system enabled to adjust the pixel size to 1, 2.5 and 4 mu m. The scans were acquired at five sample-to-detector distances: 4.5, 150, 250, 500 and 1000 mm. SNR was measured in an homogeneous region portion of the mu CT image for each combination of pixel size and propagation distance. Experimental results were compared to a theoretical model taking into account the actual point spread function of the employed imaging system. The measured gain of SNR associated with the application of the phase-retrieval matched the predictions for large Fresnel numbers (N-F > 2). For each pixel size, an optimal range of propagation distances was found. Optimal mu CT reconstructions were then compared with their respective histopatological images, showing an excellent visibility of relevant structures. The optimization performed in this study will allow to select the most appropriate geometrical configurations for future acquisitions of virtual histology images of different specimens via phase-contrast microtomography

    Non-degenerate solutions of boundary-value problems

    Full text link
    Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/23291/1/0000228.pd

    Constrained Willmore Surfaces

    Full text link
    Constrained Willmore surfaces are conformal immersions of Riemann surfaces that are critical points of the Willmore energy W=∫H2W=\int H^2 under compactly supported infinitesimal conformal variations. Examples include all constant mean curvature surfaces in space forms. In this paper we investigate more generally the critical points of arbitrary geometric functionals on the space of immersions under the constraint that the admissible variations infinitesimally preserve the conformal structure. Besides constrained Willmore surfaces we discuss in some detail examples of constrained minimal and volume critical surfaces, the critical points of the area and enclosed volume functional under the conformal constraint.Comment: 17 pages, 8 figures; v2: Hopf tori added as an example, minor changes in presentation, numbering changed; v3: new abstract and appendix, several changes in presentatio

    Insights from in\ua0vivo micro-CT analysis: testing the hydraulic vulnerability segmentation in Acer pseudoplatanus and Fagus sylvatica seedlings

    Get PDF
    The seedling stage is the most susceptible one during a tree\u2032s life. Water relations may be crucial for seedlings due to their small roots, limited water buffers and the effects of drought on water transport. Despite obvious relevance, studies on seedling xylem hydraulics are scarce as respective methodical approaches are limited. Micro\u2010CT scans of intact Acer pseudoplatanus and Fagus sylvatica seedlings dehydrated to different water potentials (\u3a8) allowed the simultaneous observation of gas\u2010filled versus water\u2010filled conduits and the calculation of percentage loss of conductivity (PLC) in stems, roots and leaves (petioles or main veins). Additionally, anatomical analyses were performed and stem PLC measured with hydraulic techniques. In A. pseudoplatanus, petioles showed a higher \u3a8 at 50% PLC (\u3a850 121.13MPa) than stems ( 122.51 MPa) and roots ( 121.78 MPa). The main leaf veins of F. sylvatica had similar \u3a850 values ( 122.26 MPa) to stems ( 122.74 MPa) and roots ( 122.75 MPa). In both species, no difference between root and stems was observed. Hydraulic measurements on stems closely matched the micro\u2010CT based PLC calculations. Micro\u2010CT analyses indicated a species\u2010specific hydraulic architecture. Vulnerability segmentation, enabling a disconnection of the hydraulic pathway upon drought, was observed in A. pseudoplatanus but not in the especially shade\u2010tolerant F. sylvatica. Hydraulic patterns could partly be related to xylem anatomical traits
    • …
    corecore